SENSOR PRESSURE SWITCH

PROOF OF CLOSURE SWITCH
รายละเอียดสินค้า

PROOF OF CLOSURE SWITCH

HGT 2000

 

 

 

DIMENSION


 

The length of the detection is based on the combined model.

 

 

DIMENSION

 MODEL

 Overall (mm)

 Weight(Kg)

 Connection

 A

 D

 HGT 20000

62 

44.5 

42.5 

104 

52.5 

4.6 

Rp 1/4" 

 

 

GENERAL SPECIFICATION

 Working gas

 LNG(Town gas), LPG, Air, Flue gas, Non-aggressive gas

 Ambient temperature

 -15 ∼ 60 ℃

 Protection grade

 IP 54

5- Dust protected

4- Protection against splashing water

 

 

MATERIALS

 Housing base

 Nylon W6

 Other parts

 HNBR, Brass etc.

 

 

COMBINED EXAMPLES

 

 
HDG Series combination

 

 

 
HGDS Series combination

 

■ TECHNICAL DESCRIPTION

 

The HGT is a mechanically activated switch for monitoring the position of the valve plate.

The product can be mounted to the following products.

      · HDG / HDG-EX

      · HDGS / HDGS-EX

      · HGS / HGSO

      · HGD

      · HGRB

The compact, robust and functional design permits a simple and quick installation, and it is essentially easy       maintenance .

All components are designed to withstand mechanical and chemical stresses present in a typical installation.

■ ATTENTION

All installation/maintenance work must be carried out by skilled staff. Always check that the system is gas-tight after installation. 

Failure to follow this manual can result in dangerous situations or damage to the product.

 

■ INSTALLATION

1. Warning

  - For proper and safe operation and long service life of the valve, consider the following recommendations      

    of the valve during the design of the system when the valve is installed

      · Rated voltage and current       

      · The degree of protection vessel

      · Dimensions of tolerance parallel thread

      · Attachment Method

      · The environment       

      · Pull method 

      · Location inlet section          

      · Using leased lines

  - Shut off the air/gas supply at the main manual

    shut-off valve and disconnect electrical power to the valve before proceeding with installation or servicing.

  - Before installation, ake sure that the pipeline is free from impurities and vibration-free.

  - Make sure all gaskets are used properly.

  - Please be sure protective measures to prevent easy access to the facilities.

  - If you do not use the Rated voltage products can cause serious malfunction. 

  - After installation, function and leaking tests must be carried out.

  - Perform maintenance must be done at least once a year.

 

2. Installation Location

  - Ensure that installing area is protected from rain or moisture and sunlight.

■ Standards and specifications of this product are subject to change without prior notice for improved performance.

 


PISTON TYPE Y ANGLE SEAT VALVE
รายละเอียดสินค้า

PISTON TYPE Y-ANGLE SEAT VALVE 
(FLANGE TYPE)

​HYP-2150F / 2160F / 2170F / 2180F / 2190F

APPLICATIONS

Piping for water or steam, Industrial machinery piping, Sterilizers, Boilers, Air conditioners, Lubricators, 

   Medical equipments, Vacuum packing

 

 

HYP 2150F / 2160F / 2170F / 2180F / 2190F

 

 

 

 

DIMENSION

 MODEL

ORIPICE(mm) 

PORT CONNECTION 

ACTUATOR SIZE (mm) 

ØD 

 ØF

 HYP-2150F

20 

20A 

50 

  145 

 -

64 

140 

75 

100 

 HYP-2160F

25 

25A 

63 

 160

 -

80 

173 

54 

125 

HYP-2170F 

32 

32A 

63 

 170

 -

80 

210 

69 

135 

 HYP-2180F

40 

40A 

63 

 183

 -

80 

260 

69 

140 

 HYP-2190F

50 

50A 

80 

 195

 -

100 

300 

84 

155 

 

 

STANDARD SPECIFICATION

  WORKING FLUID 

AIR, WATER, GAS, STEAM, CLEAN OIL 

 WORKING PRESSURE

0 ~ 1.3 MPa 

 FLUID TEMPERATUR

-10℃ ~ 180℃ 

 OPERATING PRESSURE

0.4 ~ 0.8 MPa 

 ACTING TYPE

SINGLE ACTING (SPRING RETURN) 

 BODY MATERIAL

SUS 304 

 SEAT MATERIAL

PTFE 

 OPTION

SOLENOID V/V, FILTER+REGULATOR, DOUBLE ACTING 

 

 

Specification of the products are subject to change without prior notice for quality improvement. 


Gas/Air Pressure control
รายละเอียดสินค้า

EXPLOSION PROOF GAS/AIR PRESSURE CONTROL 
(for Intermidate Pressure)

EX-HS 203 / 206 / 210 / 220 / 230

     

 

  0112adb60cd1b919fcef8939b59f24bb_1472463

According to LVD 2006/95/EC

test required IEC 60730-1 (4th Edi.): 2010 / IEC 60730-2-6 (2th Edi.): 2007

 0112adb60cd1b919fcef8939b59f24bb_1472463

Certification Criteria

                  : Protective equipment compulsory safety certification Notice

(Ministry of Employment and Labor Notice 2013-54)

Certification Number : 15-GA2BO-0944X

Certification ratings : Ex d IIC T4 IP67

 

 

DIMENSION

 0112adb60cd1b919fcef8939b59f24bb_1472463 

 

 

APPLICATION 

Explosion-proof box of this product has received safety certification from Korea Gas Safety Corporation to 

produce and mount a 3rd party pressure control (pressure switch) at the request of the consumer.

 

 

GENERAL SPECIFICATION

 Ambient temperature

 Air, Water, Fluorinated refrigerants

 Ambient temperature

 -15 ∼ 60 ℃

 Medium temperature

 -10 ~ 120 ℃

 Contact mechanism

 SPDT

 Protection grade

 IP 67

6- Dust tight, No ingress of dust

7- Protection against strong jets of water from all 

directions.

 

 

MATERIALS

 Explosion-proof housing

 Aluminium diecast

 Internal housing base

 Iron

 Bellows

 Bronze

 Connection port

 Brass

 Diaphragm  

 HNBR

 Pressure connection

 Stainless steel

 

 

TECHNICAL SPECIFICATION

 MODEL

Pressure Range 

Differential Range

     

       Factory 

   Setting On/Off

 

Max. 

Bellows Pressure

Switch Action 

 Bar

Psig 

 Bar

Psig 

 Bar

Psig 

 Bar

Psig 

 EX-HS 203

 -0.5 to 3

20 to 43 

 0.35 to 2

 5 to 30

 0.5/1.5

7/21 

 11

160 

 Auto Type SPDT opens

 High/Low Action

 EX-HS 206

 -0.5 to 6

 20 to 87

 0.6 to 4

 9 to 58

 1.5/2.5

 29/43

 16.5

 240

 EX-HS 210

 1 to 10

 15 to 145

 1 to 3

 15 to 43

 4/6

 58/87

 16.5

 240

 EX-HS 220

 5 to 20

 73 to 290

 3 to 5

 43 to 72

 12/15

 174/217

 40

 580

 EX-HS 230

 5 to 30

 73 to 435

 3 to 10

 43 to 145

 15/20

 217/290

 40

 580

 

 

ELECTRICAL FUNCTION

    Rated Voltage

 

 

 Rated Current

 

Power Factor

cosϕ

 

 AC

 DC

 125

250 

450 

25 

125 

 Non-Inductive Current

10 

0.5 

 Inductive Current

Running Current

 0.75

8.5 

4.5 

0.2 

Rocked Roter Current

  0.45 

40 

20 

10 

10 

 

 

PRESSURE ADJUSTING

1 

 

 

 

[Figure1]

 [Figure1] Open the cap of pressure range adjusting screw 

and the differential pressure adjusting screw.

 


 

If any flammable materials are around, never open.

Make sure that the power is completely shut off.

 

 

[Figure 2]

 [Figure 2] Loosen the lock as a hexagon wrench and turn the open.


  


         [Figure 3]                [Figure 4] 

 


 

[Figure 4]. Insert a screwdriver into the screw hole of the open differential pressure regulation 

and pressure ranges, such as turning the screw to adjust the pressure.

 

     - After pressure adjustment,

       be sure to close the lid of the compartment and tighten the cap of screw for the explosion-proof features.

 

 

 

                          

1. Turn the pressure range adjusting screw to suit the 

   maximum pressure required.

 

2. Turn the differential pressure adjusting screw to suit 

   the needs of differential pressure 


3. While operating within a set pressure range, it will be 

  ON state  if it reaches the set differential pressure.

 

 

■ ATTENTION

All installation/maintenance work must be carried out by skilled staff. Always check that the system is gas-tight after installation. 

Failure to follow this manual can result in dangerous situations or damage to the product.

 

 

■ INSTALLATION

1. Warning

  - Select a product based on the operating pressure,depending on the model specifications table in

     this manual before installation.

  - All the gas supply must be shut off before installation.

  - Make sure that the pipeline is free from impurities and vibration-free before installation.

  - Only the "Pressure adjusting screw" and "Differential pressure adjusting screw" can be adjusted.

  - Do not bend sharply when pipe connections occur.

  - Keep the line length slightly longer to prevent vibration.

  - Before opening be aware of risks of dangerous ignition. 

  - Close the cover tightly before operating.

  - Function and holding tests must be carried out after installation.

  - When installing to ammonia system, please contact us.

 

 

2. Installation Location

  - This product can be installed in any position.

 

 

■ ADJUSTMENT

Before connecting the pipe, adjust setting value first.

 

 

■ Standards and specifications of this product are subject to change without prior notice for improved performance.


PRESSURE SWITCH (Sigle / dual type)
รายละเอียดสินค้า

PRESSURE SWITCH 
(SINGLE TYPE / DUAL TYPE)

HS - 203 / 206 / 210 / 220 / 230

HS - 306 / 306M / 606 / 606M


FEATURES

Use for air, water, fluorinated refrigerants (Allowable Fluid Temp : -10~120℃)

micro-switch ensures reliable switching.

Mounting bracket supplied as standard.

SPDT contact mechanism

 

 

APPLICATIONS 

Compressor, Firefighting equipment, Pumps, Boilers, Cooling & Heating machine and various Industrial hydraulic machinery, etc

 

 

  



 

 Pressure rise

 


 



 

 Pressure rise


 

 

RATED VOLTAGE

                 RATED VOLTAGE(V) 

 POWER FACTOR

 AC

 DC

RATED CURRENT(AMPS)

 125

 250

 450

 25

  125 

 NON-INDUCTIVE CURRENT

 1

 10

 5

  2 

  5 

  0.5 

 INDUCTIVE CURRENT

 RUNNING CURRENT

 0.75

 8.5

 4.5

 1

 2

 0.2

 LOCKED ROTER CURRENT

 0.45

 40

  20 

 10

 10

 5

 

 

PRESSURE CONNECTIONS

 

 

 

STANDARD SPECIFICATION

 TYPE

MODEL 

 PRESSURE 

RANGE

 DIFFERENTIAL 

PRESSURE RANGE

 FACTORY 

SETTING 

 BELLOWS MAX.

 PRESSURE

WEIGHT

(kg) 

 

BAR 

PSIG 

BAR 

PSIG 

BAR 

PSIG 

 BAR

PSIG 

 SINGLE TYPE /

 AUTO TYPE

  HS- 203

-0.5 to 3 

20 to 43 

0.35 to 2 

 5 to 30

 0.5 / 1.5

7 / 21 

 11

160 

    0.42

  HS-206

 -0.5 to 6

 20 to 87

 0.6 to 4

 9 to 58

 1.5 / 2.5

 29 / 43

 16.5

 240

  HS-210

 1 to 10

 15 to 145

 1 to 3

 15 to 43

 4 / 6

 58 / 87

 16.5

 240

  HS-220

 5 to 20

 73 to 290

 3 to 5

 43 to 72

 12 / 15

 174 /2 17

 40

 580

   HS-230  

 5 to 30

 73 to 435

 3 to 10

 43 to 145

 15 / 20

 217 / 290

40

580

 DUAL

TYPE

 HS-306

  L/S

 -50cmHg

 6

 0.6

 4

 2

 16.5

  - 

 0.61

  H/S

 8

 30

 Approx.4 fixed

 16

20 

 40

 -

 HS-306M

  L/S

 -50cmHg

 6

0.6 

 2

 16.5

 -

  H/S

 8

 30

 Manual Reset

16 

 Manual Reset

 40

 -

 HS-606

  L/S

 -50cmHg

 6

 0.6

 2

3

 16.5

 -

  H/S

 8

 30

 Approx.4 fixed

 16

 20

 40

 -

 HS-606M

  L/S

 -50cmHg

 6

0.6 

 2

 3

 16.5

 -

  H/S

 8

สินค้


FLOW SWITCH
รายละเอียดสินค้า

FLOW SWITCH

HFS-15 / 20 / 25

 

FEATURES

The paddle type SPDT HFS series are designed to provide excellent performance where accuracy, reliability, 

   and rugged constructiuon are required in liquid flow lines carrying water for any fiuid neither harmful to 

   brass and prosphor bronze nor classified as a hazaardous fluids.

They can be wired to close one circuit and open the other circuit when liquid flow either exceeds or drops 

   below the adjusted flow rate.

The HFS series are recommended for liquid pressure and temperature as mentioned below and must not be 

   used on fluid bellow 0℃

These series may be used on liquids with high salt or chlorine content but is not for use in hazardous atmospheres.

Flow switches are designed for use only as operating controls.

Since control failure can cause personal injury or property damage, users should use the monitoring system to 

   alert control failure or the safety equipment.

 

 

 

 

 

DIMENSION

 MODEL

CONNECTION

L1 

L2 

L3 

 HFS-15

 79

  64 

  93 

  56 

R 1/2"(PT 1/2") 

  50 

 43 

 -

  28 

 HFS-20

 79

 64

 93

 56

 R 3/4" (PT 3/4")

 50

 43

  40 

 28

 HFS-25

 79

 64

 93

 56

 R 1" (PT 1")

 89

 59

 35

 28

 

 

SPECIFICATION

 OPERATING PRESSURE

1.0 MPa (10bar) 

 WITHSTANDING PRESSURE

 1.75 MPa (17.5bar)

 INSULATION RESISTANCE

 Over 100Ω  (DC 500Vm)

 WITHSTANDING VOLTAGE

 AC 1500V / Min

 CONTACT POINT LIFE

 1000K Cycle

 BELLOWS LIFE

 500K Cycle

 TEMPERATURE of FLUID

 Max. 100℃  (212 ℉)

 

 

ELECTRICAL FUNCTION

RATED AMPS. (A)

VOLTAGE 

RESISTANCE 

LAMP LOAD 

MOTOR LOAD 

 AC

 AC 125V

 5A

44A 

 5A

 AC 250V

 2.5A

 22A

 2.5A

 DC

 DC 115V

 0.3A

 -

 -

 DC 230V

 0.15A

 -

 -

 

 

INDIVIDUAL SPECIFICATION

 BASIC OPTIONAL

CLASSIFICATION 

FLOW CONTROL RANGE (LPM) 

 PIPE DIAMETER

mm (inch)

PADDLE 

 MINIMUM

MAXIMUM 

 ON-FLOW

OFF-FLOW 

ON-FLOW 

OFF-FLOW 

 STANDARD

 25.4 (1")

 

  15 

  8 

45 

41 

 31.7 (1"1/4)

 1

 26

 13

75

68

 38.1 (1"1/2)

 

 29

 20

105

94

 50.8 (2")

 2

 34

 17

120

105

 63.5 (2"1/2)

 

 60

 34

 210

188

 76.2 (3")

 3

 68

 30

 288

 275

 101.6 (4")

 

 128

 65

 412

 360

 121.0 (5")

 

 225

 113

 750

 652

 152.4 (6")

 

 346

 172

 1125

 975

 

  

 

 

 


 

 

 

Specification of the products are subject to change without prior notice for quality improvement.